Step 1: Visual Inspection
Check for build-up on all components of the scale.
No issueIssue
Step 2: Verify Indicator
- Keypad
- Display
- Comms
- Use a simulator to verify indicator is stable and repeating
Issue
Step 3: Verify Home Run Cable
- Inspect cable for cuts, pinches, and fraying
- Use a simulator to verify stability
Issue
Step 4: Verify Load Cells
- Inspect cables for damage
- Check load cell for physical damage
- Check mv and ohms
Issue
Step 5: Verify JBox
- Disconnect interconnect cable to isolate issue
- Check mv readings for home run and load cells
- Unplug load cells one at a time to diagnose
Issue